Carsig – Your specialist for electronics solutions

IMP.100.001.300

Impulse relay, relay center contact connected to 30, pos. triggered, 1 input.

If the supply voltage is applied to terminal 15, the relay picks up for the duration of the pulse time. If the KL.15 becomes voltage-free during the impulse, the impulse is interrupted immediately. If voltage remains at terminal 15, the pulse expires and the output is switched off after the set time.

technical data
Voltage 12V
Time period 1-30sec
Lifetime elektr. 10^5
mech. 10^6
Length [mm] 30 Millimeter
Width [mm] 30 Millimeter
Height [mm] 40 Millimeter
Tab Optional

schematic

function diagram

measurements

Scroll to Top