Carsig – Your specialist for electronics solutions

IMP.100.001.113

Impulse relay, relay center contact connected to 30, pos. triggered, 1 input.

If the supply voltage is applied to terminal 15, the relay picks up for the duration of the pulse time. The output is switched off after the set time, regardless of whether voltage is applied to terminal 15 or not.

technical data
Voltage 12V
Time period 1-10min
Lifetime elektr. 10^5
mech. 10^3
Length [mm] 30 Millimeter
Width [mm] 30 Millimeter
Height [mm] 40 Millimeter
Tab Optional

schematic

function diagram

measurements