Carsig – Your specialist for electronics solutions
- Produkt finder
- controllunits
- KSR.240.000.00
KSR.240.000.00
Compact CAN controller - universal and ideal for use in the automotive sector for applications as a decentralized function extension, as an independent PLC, as a monitoring unit or for data logging.
Inputs / outputs freely graphically programmable with CarsGraf ©.
Typical applications:
Control unit for central electrics, fuse monitoring, relay control, output / input expansions, connection of binary and analog sensors via CAN bus.
Input: up to 16
- 2 digital (optional 1 frequency input max. 1 kHz)
- 14 analog (0-10V / 0-20mA, 10 (12) bit)
Analog input
Input voltage. max: Vsupply
Input resistance: 22,68 kΩ / 33,68 kΩ at KL 30
Pullup resistance: 10 kΩ connectible via software
Pulldown resistance: 0,5 kΩ connectible via software
Input frequency: max 100 Hz
Digital input
Input voltage max: Vsupply
Switch on level: 7 VDC
Switch off level: 4,5 VDC
Input resistance: 22,6 kOhm
Input frequency: max 100 Hz
Outputs: up to 10
- 2 HSD 2A
- 6 HSD 1,5A (usable as PWM outputs)
- optional 2 Low Side 2A
Load current / overload: double the switching current for a maximum of 5 minutes
Protective circuit: integrated freewheeling diodes
PWM frequency: max. 1 kHz
Duty cycle: 0 ... 100%%
Resolution: frequency indepentent
Interfaces:
- 1 CAN High Speed (CAN Low Speed or RS232 optional)
CAN for especially harsh environments
- Overvoltage protection up to ±36 V
- Loss of ground protection, overtemperature (thermal shutdown)
- Protection, and common-mode transient
- Protection of ±100 V.
- Bus Pins Fault Protection Exceeds ±36 V
- Bus Pins ESD Protection Exceeds ±16 kV HBM
- Compatible With ISO 11898-2
Internal temperature measurement.
Internal voltage measurement.
Overcurrent detection / measurement.
CAN bus interface
according to ISO 11898-5: Highspeed wake on CAN
according to CAN 2.0 B: 29 bits extended address identifier
Baud rate: 20 kBit / s to 1000 kBit / s (250 kBit / s default value)
Some of the inputs are programmable as outputs.
Programming can be done graphically or via C development system.
The functional scope (memory / register access or bus communication) can be limited in graphic programming.
Programming with the C development system requires programming and hardware knowledge.
CAN bus high or low speed (other interfaces such as CANopen, SAE J1939, RS232 optional). Use as master, slave module or expansion (I /O).
technical data | |
---|---|
Voltage | 12V/24V |
Operating voltage | 9-30V |
Number of inputs | 16 |
Additional output | 10 |
Tab | Optional |
Length [mm] | 62 Millimeter |
Width [mm] | 62 Millimeter |
Height [mm] | 36 Millimeter |